Possible Causes

Incorrect ignition electrode gap, Dirty burner or blocked burner ports, Low inlet gas pressure, Faulty ignition transformer or module

How to Fix / Troubleshooting

Safety first: Turn off power and gas before removing burner or ignition components. Do not repeatedly reset without correcting the cause.

  • Inspect burner: Remove the burner assembly per Laars instructions. Check for rust, debris, or blocked ports. Clean with a soft brush and vacuum; do not enlarge burner ports.
  • Check electrode position: Verify the spark electrode gap and position relative to the burner as specified in the Laars service manual. Misalignment can prevent reliable ignition.
  • Examine ignition cable: Look for cracks or burn marks on the high-voltage cable. Replace if damaged.
  • Reassemble and test: Reinstall burner and electrodes, restore gas and power, and attempt a restart. If IGN-L returns, stop and call a technician.

When to call a professional: Detailed ignition diagnostics and gas pressure checks require specialized tools and training.