Intermittent Flame Sensing Problem
Boiler frequently locks out with generic flame failure but no specific F-code shown on basic models
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Marginal flame sensor signal, poor grounding, burner contamination, fluctuating gas pressure
How to Fix / Troubleshooting
Safety first: Turn off power and gas before accessing burner components.
- Clean flame sensor: Remove and gently clean the flame rod with fine abrasive pad. Reinstall and ensure a tight electrical connection.
- Check ground connections: Verify the boiler chassis ground is secure and that the burner assembly has a solid metal-to-metal connection to ground.
- Inspect burner: Clean dust and debris from the burner surface. Ensure all burner ports are open.
- Monitor gas supply: If other gas appliances cause the boiler to fail when they start, gas pressure may be marginal and should be checked by a gas technician.
Professional help: A technician can measure flame signal microamps and adjust or replace components as needed.