Boiler displays F.09, will not start, often after wiring changes or lightning
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Possible Causes
How to Fix / Troubleshooting
Safety first: Disconnect power before touching the control board or wiring.
- Power cycle: Turn off power at the service switch for at least 60 seconds, then restore. Sometimes transient faults clear with a full power reset.
- Inspect board and connections: Remove the control panel cover. Look for burnt components, discoloration, or bulging capacitors on the Lochinvar control board. Check all plug-in connectors for secure seating.
- Check grounding: Verify the boiler chassis is properly grounded and that the neutral and ground connections are tight. Poor grounding can cause control faults.
- Surge protection: If the fault followed a storm or power event, consider adding a surge protector to the boiler circuit after repair.
Professional help: F.09 typically requires control board diagnostics and replacement by a qualified technician. The replacement board must be programmed/configured per Lochinvar instructions for your specific model and gas type.
Repair Difficulty
Required Part