F.15
Lochinvar
Low Water Pressure / System Fill Fault
Boiler intermittently shows F.15, especially when multiple zones call
Advertisements
Possible Causes
Insufficient system pressure, leaking system, failed automatic fill valve, faulty pressure sensor
How to Fix / Troubleshooting
Safety first: Allow the system to cool before adding water. Hot water can cause scalding.
- Check pressure gauge: Read the boiler's pressure gauge. For most Lochinvar hydronic systems, cold pressure should be around 12–15 psi for a two-story home.
- Add water if needed: If pressure is low and you have an automatic fill valve with a manual bypass, slowly open the bypass to raise pressure to the recommended level, then close it.
- Inspect for leaks: Look for visible leaks at boiler connections, relief valve discharge, radiators, and piping. Repair leaks promptly.
- Check expansion tank: A waterlogged expansion tank can cause pressure swings. Tap the tank; if it sounds solid and heavy, it may be full of water and need service or replacement.
- Reset boiler: After restoring proper pressure, reset the boiler and monitor for recurring F.15.
Professional help: If pressure continues to drop or the pressure sensor is suspected faulty, contact a heating technician.