E03
Main Flue Fan or Air Pressure Switch Fault

Boiler shows E03 and shuts down, fan may run but burner does not light

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty fan assembly, Blocked flue or condensate trap, Defective air pressure switch, Damaged pressure tubing

How to Fix / Troubleshooting

Safety: Switch off power and isolate gas. Do not operate the boiler with suspected flue or fan faults.

  • Check flue terminal: From outside, ensure the Main boiler flue terminal is clear of obstructions (ice, leaves, plastic bags). Remove any blockage.
  • Inspect condensate pipe: In cold weather, check the external condensate pipe for freezing. If frozen, thaw gently with warm (not boiling) water and lag the pipe to prevent recurrence.
  • Listen for fan operation: On a call for heat, listen for the fan starting. No fan noise suggests a fan or PCB supply issue.
  • Engineer checks:
    • Test the fan motor on the Main boiler for correct voltage supply and rotation.
    • Inspect and replace any kinked or split silicone tubes between the fan/venturi and air pressure switch.
    • Test the air pressure switch for correct switching at specified pressures; replace if faulty.
    • Check the flue system for correct installation, slope, and integrity according to Main installation instructions.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Fan Assembly
Check Price on Amazon