Flame Loss During Operation
Boiler shows E14 and shuts down, often after a loud noise or electrical event
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Unstable gas supply, Blocked burner or injector, Faulty gas valve, Intermittent ionisation signal
How to Fix / Troubleshooting
Safety: Gas-related diagnostics must be performed by a Gas Safe engineer. Do not repeatedly reset a boiler that loses flame during operation.
- Observe pattern: Note if E14 occurs only when other gas appliances are used or at certain times of day, which may indicate supply issues.
- Check flue and ventilation: Ensure the Main flue terminal is unobstructed and that any required ventilation openings are not blocked.
- Engineer tasks:
- Check gas inlet pressure and dynamic pressure while the boiler is firing.
- Inspect and clean the burner and injectors on the Main heat exchanger.
- Test the gas valve modulation and replace the Main gas valve if it fails to maintain stable pressure.
- Verify the ionisation probe signal during operation and replace if intermittent.