E15
Main Flow/Return Temperature Differential Too High

Boiler displays E15, often with rapid temperature rise and shutdown

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Insufficient circulation, Pump running at low speed, Blocked radiators or valves, Sludged system

How to Fix / Troubleshooting

Safety: Allow the system to cool before touching pipework or radiators.

  • Open all radiator valves: Ensure TRVs and lockshield valves are open, especially on radiators near the boiler.
  • Bleed radiators: Remove trapped air from all radiators and towel rails, starting upstairs.
  • Check pump setting: If the Main boiler has adjustable pump speed, set it to a higher setting to improve circulation.
  • Engineer checks:
    • Measure temperature difference between flow and return; if excessive, inspect for blockages.
    • Clean or replace any system filters and flush the system if heavily sludged.
    • Replace the Main pump assembly if it cannot provide adequate flow.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Circulating Pump