E19
Main Internal PCB Power Supply Fault

Boiler displays E19 and will not start, often after a power surge

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Damaged PCB power supply components, Overvoltage or surge, Neutral/earth fault, Water ingress onto PCB

How to Fix / Troubleshooting

Safety: Isolate power at the fused spur. Do not attempt to repair the PCB at component level unless qualified.

  • Check supply and fuse: Confirm the correct fuse rating at the spur and that there is a stable 230V supply.
  • Inspect for water damage: Look for signs of leaks above the PCB area (e.g. from automatic air vent or pipe joints) and rectify any leaks before replacing electronics.
  • Engineer actions:
    • Test incoming voltage and earthing.
    • Replace the Main control PCB as a complete unit.
    • Fit surge protection if the installation is prone to voltage spikes.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Main Control PCB
Check Price on Amazon