E19
Main
Internal PCB Power Supply Fault
Boiler displays E19 and will not start, often after a power surge
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Damaged PCB power supply components, Overvoltage or surge, Neutral/earth fault, Water ingress onto PCB
How to Fix / Troubleshooting
Safety: Isolate power at the fused spur. Do not attempt to repair the PCB at component level unless qualified.
- Check supply and fuse: Confirm the correct fuse rating at the spur and that there is a stable 230V supply.
- Inspect for water damage: Look for signs of leaks above the PCB area (e.g. from automatic air vent or pipe joints) and rectify any leaks before replacing electronics.
- Engineer actions:
- Test incoming voltage and earthing.
- Replace the Main control PCB as a complete unit.
- Fit surge protection if the installation is prone to voltage spikes.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Main Control PCB
Check Price on Amazon
We may earn a commission from links on this page.