E016
Navien Overheat / Outlet Temperature Too High

Boiler displays E016 and stops heating, often after running for some time

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Insufficient water flow through heat exchanger, Scaled heat exchanger, Stuck or closed zone valves, Failed system pump

How to Fix / Troubleshooting

Safety first: Allow the boiler and piping to cool. Turn off power before working on pumps or valves.

  • Step 1 – Check all valves: Confirm that all isolation and zone valves are open when there is a call for heat. Manually open motorized valves if possible to test flow.
  • Step 2 – Verify pump operation: Listen and feel for the system and primary pumps running. If a pump is hot but not circulating, it may be seized and require replacement.
  • Step 3 – Clean strainers and filters: Shut off valves and clean any strainers on the boiler return or system piping. Debris can severely restrict flow.
  • Step 4 – Descale heat exchanger: If the system uses hard water and has not been maintained, the heat exchanger may be scaled. A professional can perform a chemical descaling using a pump and approved descaling solution.

Repeated E016 errors indicate a serious flow or scaling issue that should be corrected promptly to avoid heat exchanger damage.