E109
Navien Gas Valve / Gas Supply Error

Boiler shows E109 and locks out, often during ignition attempts

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Closed gas shutoff valve, Insufficient gas supply pressure, Faulty gas valve coil, Loose gas valve wiring

How to Fix / Troubleshooting

Safety first: If you smell gas, do not attempt repairs. Evacuate and contact your gas supplier and a licensed technician. Turn off power and gas before touching gas components.

  • Step 1 – Verify gas valves: Confirm the manual gas shutoff valve near the boiler and any upstream valves are fully open.
  • Step 2 – Check other gas appliances: See if stoves or other gas appliances operate normally. If not, the building gas supply may be the issue.
  • Step 3 – Inspect gas valve wiring: With power off, ensure the gas valve connector is fully seated on the valve and at the PCB.
  • Step 4 – Professional pressure test: A licensed technician should measure inlet and manifold gas pressures and test the gas valve coil resistance. Replace the gas valve if it does not open or is out of spec.

Never attempt to disassemble or manually force a gas valve open.

Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Gas Valve Assembly
Check Price on Amazon

We may earn a commission from links on this page.