E110
Navien Return Water Temperature Sensor Fault

Boiler intermittently displays E110 and stops heating, often during long runs

Advertisements

Possible Causes

Defective return thermistor, Loose sensor clamp, Damaged wiring harness, Sensor out of calibration

How to Fix / Troubleshooting

Safety first: Turn off power and allow piping to cool before handling sensors.

  • Step 1 – Locate return sensor: Find the return water temperature sensor on the return manifold or piping entering the boiler.
  • Step 2 – Inspect mounting: Ensure the sensor is firmly attached to the pipe or well and has good thermal contact (use thermal paste if specified).
  • Step 3 – Check wiring: Inspect the harness for damage and confirm the connector at the PCB is secure.
  • Step 4 – Replace sensor: If E110 persists, replace the return thermistor with a Navien‑approved part.

Incorrect temperature readings can cause poor modulation and nuisance shutdowns, so address E110 promptly.

Advertisements

Repair Difficulty

Easy 2/5

Required Part

Return Temperature Sensor (Thermistor)
Check Price on Amazon