E302
Navien Flame Detection Error (Flame Present When Not Commanded)

Boiler displays E302 and locks out, often with no ignition attempt

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Shorted flame rod to ground, Moisture or condensation on flame sensor, PCB flame detection circuit fault, Electrical noise interference

How to Fix / Troubleshooting

Safety first: Turn off power and gas before inspecting the burner or flame rod.

  • Step 1 – Inspect flame rod: Remove the flame rod and check for carbon tracking, cracks, or moisture. Clean and dry thoroughly, then reinstall.
  • Step 2 – Check wiring: Ensure the flame rod wire is not pinched or touching metal surfaces that could cause a false flame signal.
  • Step 3 – Dry combustion chamber: If there is evidence of water or condensate in the combustion chamber, inspect the condensate trap and venting for leaks or blockages and correct them.
  • Step 4 – PCB evaluation: If E302 persists with a clean, dry flame rod and good wiring, the PCB flame detection circuit may be faulty and require replacement.

Do not bypass flame safety circuits; they are critical for safe operation.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Flame Rod
Check Price on Amazon

We may earn a commission from links on this page.