Noritz
No Power / Power Supply Failure
Boiler does not power on at all; display is blank and no lights or sounds are present.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Tripped circuit breaker, Blown internal fuse on Noritz control board, Loose power wiring, Faulty transformer or power supply
How to Fix / Troubleshooting
Safety: Turn OFF power at the main panel before opening any electrical junction boxes or the boiler cabinet.
- 1. Check breaker and switch: Verify the dedicated boiler breaker is ON and any local service switch near the Noritz boiler is in the ON position.
- 2. Inspect power cord or wiring: Ensure the boiler's power cord (if equipped) is plugged in securely, or that hardwired connections are tight (electrician recommended).
- 3. Internal fuse: With power OFF, remove the front cover and locate the control board fuse. If blown, replace only with the same type and rating. If it blows again, stop and call a technician.
- 4. Professional diagnosis: If there is still no power, a technician should test incoming voltage, transformer output, and replace the control board or transformer as needed.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Control Board Fuse / Power Supply
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements