Noritz Air Entrapment in Heating System

Boiler is very noisy with gurgling sounds in pipes and radiators.

Advertisements

Possible Causes

Insufficient air elimination, Recent system refill, Leaking automatic air vent, Low system pressure drawing in air

How to Fix / Troubleshooting

Safety: Use caution when bleeding hot radiators; wear gloves.

  • 1. Check system pressure: Ensure pressure is within the recommended range. Low pressure can draw air into the system.
  • 2. Bleed radiators: Starting with the highest radiators, use a bleed key to release trapped air until water flows steadily.
  • 3. Inspect automatic air vents: Check vents near the Noritz boiler and high points for leaks or stuck caps. Replace faulty vents.
  • 4. Repeat as needed: After bleeding, recheck pressure and top up if necessary. Multiple cycles may be needed after a major refill.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Automatic Air Vent