Noritz
Control Signal / Thermostat Interface Issue
Boiler's display and controls work, but there is no call for heat from the thermostat.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Open thermostat circuit, Incorrect wiring to Noritz boiler terminals, Faulty external control relay, Broken thermostat cable
How to Fix / Troubleshooting
Safety: Turn OFF power before working on low-voltage control wiring.
- 1. Verify thermostat settings: Ensure the thermostat is set to HEAT and above room temperature.
- 2. Check wiring at boiler: Inspect the thermostat or control wires at the Noritz boiler's low-voltage terminals for loose or broken connections.
- 3. Bypass test (qualified persons only): Momentarily jumper the call-for-heat terminals at the boiler to see if it responds. Remove jumper immediately after test.
- 4. Professional troubleshooting: If the boiler responds to a jumper but not the thermostat, the thermostat or wiring is likely faulty and should be replaced.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Room Thermostat
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements