14
Noritz Thermal Fuse or Overheat Cutoff Activation

Boiler shuts down and displays error 14 after running for a short period.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Scale buildup in heat exchanger, Blocked water passages, Failed thermal fuse, Poor water circulation through boiler

How to Fix / Troubleshooting

Safety: Turn OFF power and close the water and gas valves before servicing. Surfaces may be hot.

  • 1. Check system water flow: Ensure all isolation valves around the Noritz boiler are fully open. Confirm that system pumps are running and that zone valves are open when there is a call for heat.
  • 2. Clean inlet water filter: Shut off cold water to the boiler. Remove and clean the inlet water filter screen (usually at the cold water inlet). Rinse debris and reinstall.
  • 3. Inspect for scale: If the boiler is in a hard-water area and has not been descaled, internal scale may be causing localized overheating. Plan a full heat exchanger descaling using a pump, hoses, and approved descaling solution per Noritz instructions.
  • 4. Check for restricted piping: Look for closed valves, kinked flexible hoses, or clogged strainers in the boiler loop.
  • 5. Professional service: If error 14 recurs after restoring flow and cleaning filters, the thermal fuse or overheat sensor may be damaged and must be replaced by a qualified technician.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Thermal Fuse / Overheat Sensor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements