29
Noritz Condensate Drain or Neutralizer Fault

Boiler displays error 29 and may shut down shortly after starting.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blocked condensate drain line, Full or clogged condensate trap, Saturated condensate neutralizer media, Frozen condensate line

How to Fix / Troubleshooting

Safety: Turn OFF power before working on the condensate system. Condensate is mildly acidic; wear gloves and eye protection.

  • 1. Inspect condensate line: Trace the clear or white plastic condensate hose from the Noritz boiler to the drain. Look for kinks, sags filled with water, or visible blockages. Straighten and clear as needed.
  • 2. Check condensate trap: Locate the condensate trap at the base of the boiler. Remove it per the manual, empty any debris or sludge, rinse with clean water, and reinstall securely to prevent leaks.
  • 3. Examine neutralizer: If your installation includes a condensate neutralizer cartridge, check if it is full of water or media is disintegrated. Replace the neutralizer if saturated or clogged.
  • 4. Protect from freezing: In cold climates, ensure the condensate line is insulated and pitched properly to prevent freezing. Thaw frozen sections carefully with warm towels; do not use open flame.
  • 5. Test operation: Restore power and run the boiler. If error 29 returns, the internal condensate sensor or pressure switch may require replacement by a technician.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Condensate Trap / Neutralizer Assembly
Check Price on Amazon

We may earn a commission from links on this page.