Low Load / Minimum Firing Rate Mismatch
Boiler cycles on and off when only a small zone or single radiator is calling for heat
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Boiler minimum output higher than zone load, No bypass or buffer tank, Aggressive control settings, Oversized circulator
How to Fix / Troubleshooting
Safety: This is primarily an efficiency and wear issue, not an immediate hazard.
- Adjust controls: Increase differential and adjust outdoor reset to lengthen run times.
- Hydraulic balancing: Throttle flow to small zones or add a bypass to maintain minimum flow through the boiler.
- Add buffer: For very small loads, consider adding a buffer tank sized per NTI recommendations.