NTI Control / Thermostat Interface Problem

Boiler display shows normal operation but thermostats do not call for heat or boiler does not respond to call

Advertisements

Possible Causes

Incorrect thermostat wiring, Faulty thermostat, Broken low‑voltage cable, Misconfigured control inputs

How to Fix / Troubleshooting

Safety: Turn off power before changing thermostat wiring.

  • Verify wiring: Compare thermostat wiring to the NTI installation manual. Ensure call for heat terminals are correctly used.
  • Bypass test: Temporarily jumper the call for heat terminals at the boiler. If it starts, the issue is in the thermostat or wiring.
  • Check settings: Confirm the control is configured for external thermostat operation and not locked in manual or test mode.
  • Replace thermostat: If wiring is intact and the boiler responds to a jumper, replace the thermostat.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Room Thermostat
Check Price on Amazon