NTI Condensation / Venting Appearance Issue

Boiler runs but produces visible white steam or excessive condensation at vent termination

Advertisements

Possible Causes

Normal operation in cold weather, Short vent termination, Improper vent slope causing pooling, High humidity exhaust

How to Fix / Troubleshooting

Safety: Visible vapor is often normal for condensing boilers, but pooling condensate can damage structures.

  • Check vent slope: Ensure horizontal vent sections are sloped per NTI instructions to drain condensate back to the boiler or to an approved drain.
  • Inspect termination: Confirm the vent outlet is located per code clearances from windows, doors, and walkways.
  • Monitor for leaks: Look for condensate dripping from joints; reseal or replace fittings as needed.
Advertisements

Repair Difficulty

Easy 2/5