E9
Peerless Communication Error / Internal Control Failure

Boiler control shows E9 and will not respond to thermostat calls

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty control board, loose harness between display and main board, electrical noise or grounding issue

How to Fix / Troubleshooting

Safety first: Turn off power at the breaker or service switch before opening the control panel.

Steps:

  • Inspect control wiring: Remove the front cover and check the ribbon cable or harness between the user interface/display and the main Peerless control board. Reseat connectors.
  • Check grounding: Verify the boiler is properly grounded and that neutral and ground are not reversed at the service connection.
  • Look for moisture: Check for signs of water intrusion or condensation on the control board. Correct any leaks from piping or relief valves.
  • Power cycle: Restore power and see if the code clears after a full reboot.
  • If E9 remains: The control board or display module may need replacement. This should be done by a qualified technician to ensure correct programming and safety checks.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Boiler control board
Check Price on Amazon