F5
Peerless Outdoor Sensor Fault (if equipped)

Boiler displays F5 and may cycle frequently without heating properly

Advertisements

Possible Causes

Open or shorted outdoor temperature sensor, damaged cable, incorrect sensor location

How to Fix / Troubleshooting

Safety first: Turn off power before working on low-voltage wiring.

Steps:

  • Locate outdoor sensor: Find the Peerless outdoor reset sensor on the north or northwest exterior wall.
  • Inspect cable: Check for cuts, staples through the wire, or UV damage.
  • Test sensor: Disconnect at the boiler control and measure resistance. Compare to Peerless outdoor sensor chart. Replace if out of range.
  • Bypass temporarily: Some controls allow disabling outdoor reset in the menu to restore basic operation until the sensor is replaced.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Outdoor temperature sensor