F8
Peerless Condensate Drain Blocked

Boiler displays F8 and may indicate 'Condensate Fault'

Advertisements

Possible Causes

Clogged condensate trap, kinked condensate hose, frozen condensate line, failed condensate pump (if used)

How to Fix / Troubleshooting

Safety first: Turn off power. Condensate is mildly acidic; wear gloves and eye protection.

Steps:

  • Locate condensate trap: On condensing Peerless boilers, find the plastic trap at the bottom of the heat exchanger or flue collector.
  • Clean trap: Remove the trap and flush it with clean water to remove sludge and debris.
  • Inspect hoses: Ensure condensate hoses are not kinked and slope continuously to the drain.
  • Check condensate pump: If a pump is used, verify it runs and discharges water. Clean or replace if stuck.
  • Reassemble and test: Reinstall the trap, restore power, and reset the boiler.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Condensate trap
Check Price on Amazon