E06
Potterton DHW Thermistor / NTC Sensor Fault

Boiler shows E06, hot water temperature unstable or boiler shuts down during hot water demand

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty domestic hot water NTC sensor, Loose or corroded sensor connector, Damaged sensor wiring, PCB input fault

How to Fix / Troubleshooting

Safety first: Isolate power before removing the boiler front cover.

User checks:

  • Run a hot water tap and observe if the boiler attempts to fire before the error appears.
  • Reset the boiler once and see if hot water returns temporarily.

Engineer checks:

  • Locate the DHW NTC sensor on the domestic hot water outlet or plate heat exchanger.
  • Measure sensor resistance at known temperatures and compare with Potterton specifications.
  • Inspect wiring harness and connector for damage or moisture ingress.
  • Replace the DHW NTC sensor if readings are out of range or intermittent.
  • If sensor is OK, test continuity back to the PCB and evaluate PCB function.

A faulty DHW sensor is a common cause of E06 and is usually resolved by sensor replacement.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

DHW NTC Thermistor
Check Price on Amazon

We may earn a commission from links on this page.