E10
Potterton
Low Water Pressure / System Pressure Fault
Boiler shows E10, system pressure gauge low, boiler will not fire
Advertisements
Possible Causes
Insufficient system pressure, Leak in central heating circuit, Faulty pressure sensor, Faulty filling loop
How to Fix / Troubleshooting
Safety first: Allow the system to cool before topping up pressure to avoid scalding.
User checks:
- Check the pressure gauge on the boiler; if below 1.0 bar, top up using the filling loop until 1.0–1.5 bar when cold.
- Reset the boiler after topping up and check for normal operation.
- Walk around the property and look for visible leaks on radiators, valves, and pipework.
Engineer checks:
- Inspect the boiler and system for hidden leaks, including underfloor pipework and around the pressure relief valve discharge pipe.
- Test the pressure sensor or pressure switch for correct operation and replace if faulty.
- Check the filling loop for slow filling or backflow issues; replace if defective.
If pressure repeatedly drops, a leak or expansion vessel issue is likely and should be investigated by a heating engineer.