E160
Potterton
Fan Fault / No Fan Feedback
Boiler shows E160, fan-related error, boiler will not fire
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Fan not running, Fan speed sensor failure, Loose fan wiring, PCB fan control failure
How to Fix / Troubleshooting
Safety first: Isolate power before accessing the fan compartment.
User checks:
- Reset the boiler and listen for the fan starting; report any unusual noises.
Engineer checks:
- Check for correct voltage at the fan terminals when a demand is present.
- Inspect fan blades for obstruction and check that the shaft spins freely.
- Test fan speed feedback signal and wiring continuity.
- Replace the fan assembly if it fails to start or provide feedback; if fan is OK, suspect PCB.
Fan faults must be rectified before the boiler can operate safely.