E20
Potterton External Control / Thermostat Fault

Boiler shows E20 and will not start, often after wiring changes or thermostat replacement

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Incorrect room thermostat wiring, Open circuit on call-for-heat terminals, Faulty external controls, PCB input fault

How to Fix / Troubleshooting

Safety first: Isolate power before accessing wiring terminals.

User checks:

  • Ensure the programmer is set to ON and the room thermostat is turned up above room temperature.
  • Check any external controls (e.g., wireless receiver) for batteries and status lights.

Engineer checks:

  • Verify correct wiring of room thermostat and programmer to the boiler's low-voltage control terminals.
  • Link out the call-for-heat terminals at the boiler to test if it fires without external controls.
  • Check continuity of control cables and replace if damaged.
  • Replace faulty external controls or, if necessary, investigate PCB input issues.

Correct wiring and control configuration are essential for safe boiler operation.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Room Thermostat / Control Wiring
Check Price on Amazon