E28
Potterton Condensate Drain / Trap Fault

Boiler shows E28, often associated with condensate issues or blocked trap

Advertisements

Possible Causes

Blocked condensate trap, Frozen external condensate pipe, Incorrect condensate pipe fall, Trap not filled with water

How to Fix / Troubleshooting

Safety first: Isolate power. Condensate is mildly acidic; wear gloves and eye protection when handling.

User checks:

  • Inspect the external condensate pipe for freezing in cold weather; thaw gently with warm water and lag the pipe.

Engineer checks:

  • Remove and clean the condensate trap; flush with clean water and ensure it is refilled before refitting.
  • Check the condensate pipework for correct fall and absence of sags or blockages.
  • Verify that the trap seals correctly and no air is being drawn through.

Once the condensate path is clear and the trap is refilled, reset the boiler and test operation.