E40
Potterton Communication / Internal Bus Fault

Boiler displays E40, no response to control inputs, may be after power cut

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty display PCB, Loose ribbon cable between PCBs, Main PCB communication failure, Power supply instability

How to Fix / Troubleshooting

Safety first: Turn off power at the fused spur before opening the boiler case.

User checks:

  • Turn power off for 5 minutes, then back on to perform a hard reset.

Engineer checks:

  • Inspect and reseat any ribbon cables or connectors between the main PCB and display/control PCB.
  • Check supply voltage and earth quality at the boiler terminals.
  • Substitute known-good display PCB or main PCB as per Potterton diagnostic procedure.

Communication faults typically require PCB or harness replacement by a qualified engineer.

Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Display PCB
Check Price on Amazon

We may earn a commission from links on this page.