E40
Potterton
Communication / Internal Bus Fault
Boiler displays E40, no response to control inputs, may be after power cut
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Faulty display PCB, Loose ribbon cable between PCBs, Main PCB communication failure, Power supply instability
How to Fix / Troubleshooting
Safety first: Turn off power at the fused spur before opening the boiler case.
User checks:
- Turn power off for 5 minutes, then back on to perform a hard reset.
Engineer checks:
- Inspect and reseat any ribbon cables or connectors between the main PCB and display/control PCB.
- Check supply voltage and earth quality at the boiler terminals.
- Substitute known-good display PCB or main PCB as per Potterton diagnostic procedure.
Communication faults typically require PCB or harness replacement by a qualified engineer.
Advertisements
Repair Difficulty
Professional Required
5/5