E60
Potterton Diverter Valve Position Fault

Boiler displays E60, hot water priority or diverter valve related issues, heating may not work

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Stuck diverter valve, Faulty diverter motor head, Sludge in valve body, Position microswitch failure

How to Fix / Troubleshooting

Safety first: Isolate power and close isolation valves if removing any water components.

User checks:

  • Observe whether hot water works but heating does not, or vice versa, and report this to the engineer.

Engineer checks:

  • Manually exercise the diverter valve to see if it moves freely.
  • Check the motorised head for operation when switching between DHW and CH demands.
  • Inspect and clean the valve body if sludge is present; replace if seized.
  • Test any position microswitches for continuity and replace the motor head if faulty.

Restoring correct diverter operation will usually clear E60 faults.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Diverter Valve Assembly
Check Price on Amazon