Potterton
Unstable DHW Temperature Control
Hot water temperature fluctuates or runs hot then cold during shower use
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Partially blocked plate heat exchanger, Faulty DHW NTC sensor, Inadequate flow rate, Thermostatic mixing valve issues
How to Fix / Troubleshooting
Safety first: Beware of sudden hot water temperature spikes that can cause scalding.
User checks:
- Ensure the hot tap or shower is fully open to maintain a steady flow.
- Avoid mixing hot and cold at the shower if the boiler is sensitive to low flow; adjust at the boiler controls instead.
Engineer checks:
- Check DHW NTC sensor readings and replace if faulty.
- Inspect and descale or replace the plate heat exchanger.
- Verify minimum flow rate through the boiler and adjust any flow restrictors if necessary.
- Check external thermostatic mixing valves for correct operation.
Stable DHW temperature depends on clean heat exchangers and accurate sensing.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Plate Heat Exchanger
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements