Possible Causes
Oversized boiler relative to system, Incorrect minimum output setting, Faulty temperature sensor causing premature shutdown, Poor circulation or blocked bypass
How to Fix / Troubleshooting
Safety: Isolate power and gas before internal checks.
Steps:
- Ensure all radiators and circuits are open to provide sufficient load.
- Check system pressure and bleed air to improve circulation.
- A technician can adjust boiler parameters (minimum output, pump overrun) via the service menu to reduce short cycling.
- Test NTC sensors for correct readings and replace if faulty.
- Verify that any automatic bypass valve is correctly set and not fully closed.