F25
Protherm Flue Gas Overtemperature / Flue Blockage Detected

Boiler shows F25 and locks out, often accompanied by fan running at high speed

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Partially or fully blocked flue, Incorrect flue installation or length, Faulty flue gas temperature sensor, Fan not providing correct airflow

How to Fix / Troubleshooting

Safety: Risk of carbon monoxide. Do not operate the boiler until the flue system has been checked by a qualified technician.

Steps (technician only):

  • Inspect the entire flue route, including terminal, for obstructions, disconnections, or signs of condensation damage.
  • Verify that the flue length and configuration comply with Protherm specifications.
  • Check the flue gas temperature sensor for correct mounting and resistance. Replace if faulty.
  • Test the fan for correct speed and airflow. Replace if underperforming.

After repair: Perform combustion analysis and confirm that F25 does not recur under full load.

Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Flue System
Check Price on Amazon