F26
Protherm Gas Valve Regulation Fault

Boiler displays F26, burner does not light or shuts down unexpectedly

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Defective gas valve modulating coil, Incorrect gas valve adjustment, Wiring fault between PCB and gas valve, Faulty PCB gas control circuit

How to Fix / Troubleshooting

Critical safety: Only a licensed gas technician may work on gas valves and combustion settings.

Checks:

  • Inspect the gas valve and its electrical connector for damage or loose contacts.
  • Measure the resistance of the gas valve coils and compare with Protherm specifications. Replace the gas valve if out of range.
  • Check wiring continuity from the PCB to the gas valve.
  • If the valve and wiring are OK, the PCB may be faulty and require replacement.
  • After replacing the gas valve, perform full combustion setup and gas rate adjustment according to Protherm procedures.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Gas Valve
Check Price on Amazon

We may earn a commission from links on this page.