F26
Protherm
Gas Valve Regulation Fault
Boiler displays F26, burner does not light or shuts down unexpectedly
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Defective gas valve modulating coil, Incorrect gas valve adjustment, Wiring fault between PCB and gas valve, Faulty PCB gas control circuit
How to Fix / Troubleshooting
Critical safety: Only a licensed gas technician may work on gas valves and combustion settings.
Checks:
- Inspect the gas valve and its electrical connector for damage or loose contacts.
- Measure the resistance of the gas valve coils and compare with Protherm specifications. Replace the gas valve if out of range.
- Check wiring continuity from the PCB to the gas valve.
- If the valve and wiring are OK, the PCB may be faulty and require replacement.
- After replacing the gas valve, perform full combustion setup and gas rate adjustment according to Protherm procedures.