E17
Remeha
Sensor mismatch / temperature differential error
Boiler shows E17 and cycles on and off rapidly
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Flow and return sensors reading unrealistic difference, Air lock in primary circuit, Blocked or partially blocked heat exchanger, Pump running at incorrect speed
How to Fix / Troubleshooting
Safety first: Allow the boiler to cool before bleeding or opening any components.
- Bleed system thoroughly: Remove air from radiators and any high points. Re-pressurise the system as needed.
- Check pump setting: On models with adjustable pump speed, ensure the pump is set according to system requirements (usually medium or auto).
- Engineer tasks: Compare flow and return NTC readings via diagnostics, clean or flush the primary heat exchanger if blocked, and verify correct pump operation and sizing.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Primary Heat Exchanger
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements