Rheem No Power / Dead Boiler

Boiler does not start at all, display is blank

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Tripped breaker or blown fuse, Faulty power switch on boiler, Loose power wiring, Failed main control PCB power supply section

How to Fix / Troubleshooting

Safety first: Use caution when working with mains voltage. Turn off power at the breaker before opening electrical compartments.

  • Step 1 – Check breaker: Verify that the circuit breaker feeding the Rheem boiler is on and not tripped. Reset if necessary.
  • Step 2 – Inspect external switch: Many boilers have a local disconnect or service switch. Ensure it is in the ON position.
  • Step 3 – Test power at boiler: With a multimeter and appropriate safety precautions, confirm that correct voltage is present at the boiler’s power terminals.
  • Step 4 – Internal fuses: With power off, inspect any internal fuses on the main PCB. Replace blown fuses only with identical ratings and investigate the cause.
  • Step 5 – PCB replacement: If power is present at the board but the display remains dead, the main control PCB or display board may have failed and require replacement.

Warning: If fuses blow repeatedly, do not continue replacing them. There is likely a short circuit that must be diagnosed by a professional.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Main Control PCB
Check Price on Amazon