Possible Causes
Oversized boiler relative to system, Faulty temperature sensor or thermostat, Poor system water volume, Incorrect control settings
How to Fix / Troubleshooting
Safety: Short cycling reduces efficiency and can damage components over time.
- Check controls: Ensure room thermostat and TRVs are correctly set and not located too close to the boiler or heat sources.
- System volume: If many radiators are turned off, open more to increase water volume and heat demand.
- Sensor check: Have a technician verify NTC sensor readings and replace if they are out of specification.
- Professional assessment: A heating engineer can adjust boiler parameters (if available) and assess whether system modifications (e.g., buffer tank) are needed.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Flow NTC Sensor