Riello
Flow Restriction Under Load
Boiler starts normally but shuts down when multiple radiators heat up
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Undersized circulation pump, Blocked system filter, Partially closed isolation valves, Sludge build-up in return pipe
How to Fix / Troubleshooting
Safety: Allow the system to cool before handling valves or filters.
- Check isolation valves: Ensure the boiler flow and return isolation valves are fully open.
- Clean filters: Service any inline strainers or magnetic filters on the return.
- Pump speed: Increase pump speed setting if adjustable and appropriate for the system.
- Professional system clean: If problems persist, a heating engineer should flush the system and verify pump sizing.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Primary Circulation Pump
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements