Riello
No Power to Boiler
Boiler will not start at all, no lights or display, completely dead
Advertisements
Possible Causes
Blown 3A/5A fuse in fused spur, Tripped circuit breaker, Faulty boiler on/off switch, Loose live/neutral connection at terminal block
How to Fix / Troubleshooting
Safety: Electrical work should be done with the supply isolated and by competent persons.
- Check external switch: Ensure the boiler's fused spur or isolator is switched ON.
- Inspect fuse: Turn off the spur, remove the fuse, and check/replace with the correct rating (often 3A). Do not fit a higher-rated fuse.
- Consumer unit: Check that the relevant MCB or RCD has not tripped. Reset if safe to do so.
- Terminal block: With power isolated, remove the boiler front panel and verify that live, neutral, and earth are securely connected at the boiler terminal block.
- Professional help: If power is present at the boiler but it remains dead, the internal PCB or transformer may have failed and should be tested by a technician.
Advertisements
Repair Difficulty
Easy
2/5