Overheat Thermostat Tripped
Boiler locks out with overheat indication, flow temperature very high, boiler very hot to touch on flow pipe
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Blocked or closed system valves, Failed circulation pump, Air lock in primary circuit, Faulty overheat thermostat or NTC sensor
How to Fix / Troubleshooting
Safety: Turn off power and allow the boiler to cool fully before touching any pipework. Do not remove any safety devices or bypass thermostats.
- Check system valves: Ensure all radiator and isolation valves on the flow and return near the boiler are open. A closed valve can cause rapid overheating.
- Bleed air: Bleed air from radiators and any automatic air vents near the boiler. Re-pressurise the system to the recommended cold pressure (typically 1.0–1.5 bar) using the filling loop.
- Check circulation pump: Listen for the pump running when there is a heat demand. Carefully touch the pump body (once cool) to feel for vibration. If silent and cold, the pump may be seized or not powered.
- Reset overheat stat: Locate the manual reset overheat thermostat on the boiler (often a red button on the front of the primary heat exchanger). Once cooled, press to reset. If it trips again, do not continue to reset—find and fix the cause.
- Call a technician: If overheating persists, a professional should check pump operation, system flow, and replace the overheat thermostat or NTC sensor if faulty.