A11
Riello
False Flame Signal / Ionisation Fault
Boiler shows flame present when there should be none, or fails to start due to false flame detection
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Shorted ionisation electrode to earth, Moisture or soot bridging electrode, Faulty burner control box, Incorrect earthing of boiler
How to Fix / Troubleshooting
Safety: Isolate power and fuel. Do not attempt to run the boiler with suspected electrical faults.
- Inspect ionisation electrode: Remove and clean the electrode. Ensure the ceramic insulator is intact and that the metal rod is not touching the burner head or other metal parts.
- Check cable routing: Ensure the ionisation lead is not damaged or rubbing on sharp edges. Replace if insulation is compromised.
- Dry moisture: If there is condensation or water inside the burner compartment, dry thoroughly and identify the source of ingress.
- Earth connection: Verify that the boiler and burner are properly earthed. Loose earth connections can cause erratic flame detection.
- Professional diagnosis: If the issue persists, a technician should test the burner control box and replace it if necessary.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Riello Burner Control Box
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements