A20
Riello High System Pressure

Boiler indicates high system pressure, may discharge water from safety valve and shut down

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Overfilled system via filling loop, Faulty expansion vessel (no air charge), Stuck pressure relief valve, Faulty pressure sensor calibration

How to Fix / Troubleshooting

Safety: Hot water may discharge from the safety valve. Keep clear of discharge pipe outlets.

  • Check pressure gauge: If pressure is above 2.5–3.0 bar when hot, the system is over-pressurised.
  • Drain excess water: Bleed water from a radiator or drain point until the cold pressure returns to around 1.0–1.5 bar.
  • Check filling loop: Ensure both valves on the filling loop are fully closed and that the hose is removed if required by local regulations.
  • Expansion vessel: If pressure rises sharply from cold to hot, the expansion vessel may have lost its air charge. A technician should check and recharge or replace it.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Expansion Vessel