12
Rinnai Flame Loss During Operation

Boiler starts to ignite, flame appears briefly, then shuts down and shows error 12.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Unstable gas pressure, Dirty or partially blocked main burner, Faulty flame rod (flame sensor), Poor ground connection on control board

How to Fix / Troubleshooting

Safety first: Isolate electrical power and gas before removing covers. Allow the boiler to cool.

  • Check gas supply stability: If other gas appliances flicker or go out, contact your gas supplier to check for pressure issues.
  • Inspect flame rod connection: Remove the front panel and locate the flame rod lead. Ensure the connector is firmly seated and free of corrosion. Do not bend the rod.
  • Clean burner area: Using a soft brush and vacuum, gently remove dust from the burner surface and combustion chamber. Do not use water or solvents inside the combustion chamber.
  • Verify grounding: Confirm that the boiler is properly grounded at the electrical supply and that the ground wire to the control board is secure.
  • Reset and monitor: Restore power and gas, reset the boiler, and observe operation. If error 12 recurs, the flame rod or control board may need professional testing and replacement.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Flame Rod (Flame Sensor)
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements