14
Rinnai Thermal Fuse or Overheat Cutoff Trip

Boiler locks out with error 14; unit may overheat and shut down shortly after firing.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blocked primary heat exchanger, Scale buildup in water passages, Failed thermistor or overheat sensor, Circulation pump failure causing low flow

How to Fix / Troubleshooting

Safety first: Turn off power and gas. The boiler and pipework may be extremely hot; allow full cooling before touching any components.

  • Check system water flow: Ensure all isolation valves on the boiler flow and return are fully open. Verify that radiators or heating circuits are not manually shut off.
  • Bleed air from system: Airlocks can cause localized overheating. Bleed air from radiators and any automatic air vents near the boiler.
  • Inspect circulation pump operation: With power restored briefly, listen and feel for the pump running when there is a heat demand. If the pump is silent or excessively noisy, it may be seized or failing and should be replaced by a technician.
  • Descale heat exchanger (professional recommended): Heavy scale in Rinnai condensing heat exchangers requires chemical flushing with appropriate descaling agents and pumps. This should be done by a qualified technician to avoid damage.
  • Do not bypass safety devices: Never attempt to bypass thermal fuses or overheat thermostats. If error 14 persists, have the thermistors and overheat cutoff checked and replaced as needed.