32
Rinnai
Outlet Thermistor Fault
Boiler displays error 32 and will not operate or modulates incorrectly.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Open or shorted outlet thermistor, Loose thermistor clip on outlet pipe, Damaged thermistor wiring, Faulty control PCB input
How to Fix / Troubleshooting
Safety first: Turn off power and allow the boiler to cool before touching any pipework.
- Locate outlet thermistor: This sensor is attached to the hot water or flow outlet pipe from the boiler.
- Verify physical contact: Ensure the thermistor is firmly clipped or inserted into the well on the outlet pipe for accurate temperature reading.
- Inspect wiring and connectors: Check for broken insulation, loose plugs, or corrosion at the sensor and control board ends.
- Reset and observe: Restore power, reset the boiler, and monitor operation. If error 32 returns, replace the outlet thermistor.
- Professional check: If a new thermistor does not resolve the issue, the control PCB may require replacement.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Outlet Thermistor
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements