91
Rinnai
Gas Supply or Gas Valve Fault
Boiler shows error 91 and will not ignite; may be associated with low gas supply conditions.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Insufficient inlet gas pressure, Blocked gas filter, Faulty gas valve, Gas line undersized for boiler input
How to Fix / Troubleshooting
Safety first: Turn off power and gas. Do not attempt repeated ignition if gas supply is suspect.
- Verify gas cock position: Ensure the isolation valve at the boiler is fully open.
- Check other gas appliances: If stoves or other heaters are weak or not working, contact your gas supplier to check supply pressure.
- Inspect gas line sizing (visual): Confirm that the gas pipe to the boiler appears appropriately sized and free of obvious damage or kinks.
- Professional testing: A technician should measure inlet and manifold pressures, clean or replace any gas filters, and test the gas valve operation.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
Gas Valve Assembly
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements