91
Rinnai Gas Supply or Gas Valve Fault

Boiler shows error 91 and will not ignite; may be associated with low gas supply conditions.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Insufficient inlet gas pressure, Blocked gas filter, Faulty gas valve, Gas line undersized for boiler input

How to Fix / Troubleshooting

Safety first: Turn off power and gas. Do not attempt repeated ignition if gas supply is suspect.

  • Verify gas cock position: Ensure the isolation valve at the boiler is fully open.
  • Check other gas appliances: If stoves or other heaters are weak or not working, contact your gas supplier to check supply pressure.
  • Inspect gas line sizing (visual): Confirm that the gas pipe to the boiler appears appropriately sized and free of obvious damage or kinks.
  • Professional testing: A technician should measure inlet and manifold pressures, clean or replace any gas filters, and test the gas valve operation.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Gas Valve Assembly