Ruud System Water Leak

Boiler or nearby piping is leaking water onto the floor

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Leaking pressure relief valve, corroded heat exchanger, failed gasket on sensor or manifold, loose union or drain valve

How to Fix / Troubleshooting

Safety first: Turn off power. If the leak is severe, close the system isolation valves and allow the boiler to cool. Water may be very hot.

  • Identify leak source: Dry the area and observe where water first appears—relief valve discharge pipe, under the boiler, at a union, etc.
  • Check pressure relief valve: If water is dripping from the relief discharge, check system pressure. High pressure may indicate an expansion tank issue.
  • Tighten fittings: Carefully tighten accessible unions and drain valves slightly. Do not overtighten plastic components.
  • Replace faulty components: Relief valves, gaskets, and drain valves can usually be replaced without replacing the entire boiler. A leaking heat exchanger, however, typically requires boiler replacement.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Pressure Relief Valve
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements