Ruud DHW Production Failure (Combi Boiler)

Boiler produces no domestic hot water on a combi model, but space heating works

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty DHW flow sensor, scaled plate heat exchanger, stuck diverter valve, DHW temperature sensor failure

How to Fix / Troubleshooting

Safety first: Turn off power and close domestic water isolation valves before servicing DHW components.

  • Check for DHW demand recognition: When a hot tap is opened, the boiler should indicate DHW demand on the display. If not, suspect the DHW flow sensor.
  • Inspect DHW flow sensor: Remove and clean or replace the sensor as needed.
  • Check diverter valve operation: On some Ruud combi models, a motorized diverter valve directs heat to DHW or heating. Listen for valve movement when switching between heating and DHW. A stuck valve may need replacement.
  • Descale plate heat exchanger: If the boiler fires but water is only lukewarm, the DHW plate heat exchanger may be scaled and require professional descaling or replacement.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

DHW Plate Heat Exchanger
Check Price on Amazon