F14
Saunier Duval Gas Valve Control Fault

Boiler displays F14 and locks out, often with no ignition attempt

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Defective gas valve coil, Loose gas valve connector, PCB not supplying correct voltage to gas valve, Internal gas valve blockage

How to Fix / Troubleshooting

Safety first: Isolate gas and power. Gas valve work must be carried out by a Gas Safe / qualified engineer.

User-level checks:

  • Confirm that the gas supply to the property is available and that the boiler's gas isolation valve is open.

Technical checks (engineer only):

  • Measure voltage at the gas valve during ignition demand.
  • Check coil resistance and continuity.
  • Inspect wiring between PCB and gas valve.
  • Replace the gas valve if defective and set burner pressures according to Saunier Duval specifications.

Warning: Do not attempt to open or adjust the gas valve yourself. This is a critical safety component.

Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Gas Valve
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements