E06
Sime DHW Temperature Sensor (NTC) Fault

Boiler displays E06, hot water temperature fluctuates or is incorrect, heating may still work

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed DHW NTC sensor, Loose sensor connection, Damaged harness, PCB sensor circuit fault

How to Fix / Troubleshooting

Safety first: Turn off power before accessing internal components.

  • Check symptom: Run a hot tap. If the boiler attempts to fire but shuts down with E06, the DHW sensor is likely at fault.
  • Inspect DHW NTC: On Sime combi boilers, the DHW NTC is usually clipped to the DHW outlet pipe or mounted on the plate heat exchanger. Check for secure mounting and intact wiring.
  • Clean and reseat: If there is scale or corrosion, gently clean the contact area and reseat the sensor plug.
  • Measure resistance (engineer task): Compare the NTC resistance to the manufacturer’s chart. Replace if readings are inconsistent or intermittent when the cable is flexed.
  • PCB check (engineer task): If a known-good sensor still gives E06, the main PCB input may be defective and require replacement.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

DHW NTC Temperature Sensor
Check Price on Amazon

We may earn a commission from links on this page.